Eyelet Selection Criteria
ID - Inside Diameter
The eyelet inside diameter should be a .075 - .500 mm (.003"-.020")
greater than the component lead diameter.
LUF - Length Under Flange
The length of the eyelet barrel under the flange should be .630 - .890 mm
(.025" - 035") greater than the thickness of the circuit board. This added
length allows for proper protrusion when setting the eyelet.
FD - Flange Diameter
The eyelet flange diameter should be small enough to prevent interference with
adjacent lands or circuits.
OD - Outside Diameter
The clearance hole drilled through the circuit board should allow the eyelet to be
inserted without force but should not exceed .125 mm (.005") greater than
the eyelet outside diameter.
Note
Be sure to select an eyelet meeting the proper criteria. An eyelet with an
oversize flange may interfere with adjacent circuits. An eyelet that is too
short will not protrude through the circuit board for proper setting.

Figure 1: Drill out the hole using a Micro-Drill System and ball mill.
|
| 1. |
Clean the area. |
| |
| 2. |
Select an eyelet using the Eyelet Selection Criteria. Use a pin gauge and caliper to measure the existing plated hole dimensions. |
| |
| 3. |
Insert the appropriate ball mill into the Micro-Drill System. Drill out the hole removing all the plating. The drilled hole should be .025 - .125 mm (.001" - .005") larger than the eyelet O.D. (See Figure 1).
Caution
This procedure may isolate internal connections on multilayer circuit boards. |
| |
|

Figure 2: The eyelet flange can be used to secure a new circuit in place.
|
| 4. |
Clean the area. |
| |
| 5. |
Apply a small amount of liquid flux to the land or circuit on the circuit board surface, if any, and tin with solder using a soldering iron and solder. Clean the area. |
| |
| 6. |
Insert the eyelet into the hole. If a new circuit is required, the new circuit may extend into the drilled hole and the flange of the eyelet will secure the new circuit in place. (See Figure 2). |
| |
|

Figure 3: Set the eyelet using an Eyelet Press.
|
| 7. |
Select the proper setting tools and insert them into an eyelet press system. (See Figure 3). |
| |
| 8. |
Turn the circuit board over and rest the eyelet flange on the lower setting tool. |
| |
| 9. |
Apply firm even pressure to form the eyelet barrel.
Note
Inspect the eyelet flange for evidence of damage. Refer to IPC-A-610 Acceptability of Electronic Assemblies. |
| |
| 10. |
Apply a small amount of liquid flux and solder the eyelet flanges to the lands on the circuit board surface if necessary. Clean the area. Inspect for good solder flow and wetting around the eyelet flanges and lands. |
| |
|

Figure 4: Completed repair. |
| Evaluation |
| |
| 1. |
Visual examination, dimensional requirement of land diameter and inside diameter. |
| |
| 2. |