Figure 1: Precision Drill System with base plate to pin
circuit board in position while drilling out plated hole.
|
| 1. |
Identify the hole that requires rework and clean
the area.
|
| |
| 2. |
Mark the coordinates on the board surface and
pin the circuit board in place on the base plate
of the Precision Drill System. (See Figure 1).
|
|

Figure 2: Completely mill through
the hole to isolate the internal connection(s).
|
| 3.
|
Select the appropriate size end mill, drill
or ball mill and insert it into the chuck of
the Precision Drill System. The cutting tool
should be approximately 0.50 mm (.020") greater
than the plated through hole inside diameter.
Set speed to high.
|
| |
|
| |
Caution
Abrasion
operations can generate electrostatic charges. |
| |
|
| |
Note
End mills
are normally single end, two or four flute high
grade solid carbide. |
| |
|
| 4. |
Completely mill through the hole to isolate
the internal connection(s). A microscope should
be used for accuracy. (See Figure 2).
|
| |
|
| 5. |
Blow away material with air and
clean the area. |
| |
|
| 6. |
Check continuity to be sure that the internal
connection has been deleted. Also check the
continuity and inspect the neighboring circuits
to make sure that none of them have been severed
or damaged.
|
| |
|
|

Figure 3: Fill the hole with epoxy up
to and flush with the surface.
|
|
If desired
complete the following steps |
| |
|
| 7. |
Mask the opposite side with Kapton tape or flexible
mask to prevent the epoxy from flowing out the
opposite side.
|
| |
|
| 8. |
Mix the epoxy. |
| |
|
| 9. |
Fill the hole with epoxy up to and flush with
the surface. Remove excess epoxy. (See Figure
3).
|
| |
|
| |
Note
A slight overfill of epoxy may be
desired to allow for shrinkage when epoxy cures.
|
| |
|
| 10. |
Cure the epoxy per Procedure 2.7
Epoxy Mixing and Handling. |
| |
|
| |
Caution
Some components
may be sensitive to high temperature. |
| |
|
| 11. |
Clean the area |
| |
|
|

Figure 4:
Completed repair. |
| 12. |
Select an end mill or drill as needed. Insert
the cutting tool into the Precision Drill System.
Mill directly through the center of the cured
epoxy. The surface pad remaining may be used
as a target location for accuracy. A microscope
should be used during milling for accuracy.
(See Figure 4).
|
| |
|
| |
Caution
Be careful not to re-expose the internal layers
of the hole when drilling out the epoxy.
|
| |
|
| 13. |
Clean the area. Inspect the new
hole using a microscope. |
| |
|
|
Evaluation |
| |
|
| 1.
. |
Visual and electrical examination
as required |
|