| 9.
|
Position the circuit board so that it is flat
and stable. Gently place the hot bonding tip
onto the tape covering the new land. Apply pressure
as recommended in the manual of the repair system
or repair kit for 5 seconds to tack the land
in place. Carefully peel off the tape. (See
Figure 3).
|
| |
|
| 10. |
Gently place the bonding tip directly onto the
land. Apply pressure as recommended in the manual
of the repair system or repair kit for an additional
30 seconds to fully bond the land. The bonding
film is fully cured. After the bonding cycle
remove the tape used for alignment. Carefully
clean the area and inspect the land.
|
| |
|
| |
Note
Double sided and multilayer circuit
boards may require an eyelet to restore the
through connection. Refer to section 5.0 Plated
Hole Procedures.
|
| |
|
| 11. |
Carefully remove any excess bonding film inside
the plated hole using a ball mill or drill bit.
Turn the ball mill or drill bit by hand to prevent
damage to the wall of the plated through hole.
|
| |
| 12. |
Install the proper component and
solder in place. |
| |
|
| |
Note
This method is used to repair a lifted
land, but the repaired land may not have an
inter-metallic connection to the remaining plated
hole. The solder joint of the replaced component
will restore the integrity of the electrical
connection or an eyelet or buss wire may be
used. See Plated Hole Repair Procedures.
|
| |
| 13. |
Replace surface coating to match
prior coating as required. |
| |
|
|
Evaluation |
| |
|
| 1. |
Visual examination and tape test per IPC-TM-650
test method 2.4.1 (ANCI/IPC-FC-250A).
|
| |
|
| 2. |
Electrical tests as applicable. |